科立龙电子
Home Company News Service Contact us electrode consult
 
Seat:==》Home>>electrode consult
  My company is one of units that produce the selectivity electrode early.These electrodes are widely used in soil,water quality,electric power,environment,ocean and medicine ect. We will supply to superhigh character electrode. →sensitive、jarless、long service life.
KL-001A Multi-purpose electrode support

KL-001B Multi-purpose electrode support
一、Technical Specification Of The Electrode:
 
pH electrode of lab type measure range applicable temperature application(it can be add temperature compensation element according to client's need.)
E-201 0~14pH 0~60℃ The crust of PC be able to endure hit,gelatin KC1 electrolytic liquid dispense with complementarity ,in order laboratory and locale general use.
E-210C 0~14pH 0~60℃ The crust of PC be able to endure hit,it can supplement electrolytic liquid, in order laboratory and locale general use, superior testing accuracy.
SP300 0~14pH 0~80℃ vitreous material,using in measure of laboratory precision pH, The measure solution contains organic impregnant and occasion of superior temperature.it can complement KC1 electrolytic liquid.
SP600 0~14pH 0~80℃ The crust of PC be able to endure hit,gelatin KC1 electrolytic liquid dispense with complementarity, the sensitive velum of special plan.it is applicable to determine surface pH value of paper making,piece goods, skin,fruit ect.
 
ORP electrode of lab type direction electrode applicable temperature
application
SO100 ф6×2.5mm
platinic golden loop
-5~60℃ The crust of PC be able to endure hit,it can supplement electrolytic liquid, in order laboratory and locale general use to measure the oxidable reductive electricity of solution. it use to reductive medium currently.
SO300 ф6×2.5mm
platinic golden loop
-5~100℃ vitreous material, in order laboratory and locale general use to measure the oxidable reductive electricity of solution.The measure solution contains organic impregnant and occasion of superior temperature. it use to reductive medium currently.it can complement KC1 electrolytic liquid.
 
ion selective electrode type measure range applicable temperature application
6801 natrium electrode 0~6pNa 20~40℃ It is use in the department of thermoelectric mill,paper mill,hospital and aquaculture ect.
701 complex natrium electrode 0~6pNa 20~40℃ The complex electrode is made of natrium electrode and reference electrodes,use expediently.It is use in the department of thermoelectric mill,paper mill,hospital and aquaculture ect.
pF-1A fluorin electrode 10-1~10-6M
5~45℃ It is able to determine direction electrode of fluorin ion strength in solution.It is applicable to light industry,seawater and environment protection ect.
pF-1B complex fluorin electrode 10-1~10-6M 5~45℃ The complex electrode is made of fluorin electrode and reference electrodes,use expediently.It is able to determine the strength of fluorin ion in solution. It is applicable to light industry,seawater and environment protection ect
pNH3-1 ammonia electrode 10-1
5×10-6M
5~45℃ The ammonia electrode is made up of plane pH complex electrode ventilate velum.It is able to determine the content of ammonia in solution.It is applicable to fertilizer,main-water plant and aquaculture ect.
pCl-1 chlorin electrode 10-1
5×10-5M
room temperature The chlorin electrode is ion selective electrode with AgCl-Ag2S sensitive velum.It is able to measure the strength of chlorin ion in solution.It is applicable to foodstuff, alcohol,drink,medicament and sewage ect.
PCa-1 calcium electrode 10-1~10-5M room temperature The chlorin electrode is ion selective electrode with PVC velum.It is able to measure the strength of calcium ion in solution.It is applicable to the water quality of boiler,road and biochemistry ect.
 
conductance electrode of lab type constant of conductance pool measure range application(it can be add temperature compensation element according to client's need.)
DJS-0.1 0.1±0.02 0.5~200μ S The conductance electrode is measure element of conductivity meter.It is use to measure conductivity of solution. it can be add temperature compensation element to increase the measure precision according to client's need.and it is provided with the capability of temperature compensation.It is mostly applicable to electricity factory,semiconductor,pharmacy,pure-water processing,chemical industry,foodstuff drink,paper makingand sewage-water processing ect.
DJS-1 1±0.2 5~10,000μ S
DJS-10 10±2 500~200,000μS
 
industrial conductance electrode type constant of conductance pool measure range application(it can be add temperature compensation element according to client's need.)
GC100 0.01 0.05~20μS It is mostly applicable to electricity factory,semiconductor,pharmacy,pure-water processing,chemical industry,foodstuff drink,paper makingand sewage-water processing ect.
GC200 0.1 0.5~200μS
GC300 1 5~10,000μS
 
industrial pH electrode type constant of conductance pool measure range application(it can be add temperature compensation element according to client's need.)
GP100pH complex electrode (sewage) 0~14pH 5~60℃ Its ensitive ball-vesicle is semicircular.and is easy clear. It is not easy jammed.and gelate electrolyte,not need complement KCL.It is mostly used in industry and environment protection ect.
GP400pH complex electrode (pure-water) 2~12pH 0~60℃ The complex electrode is not need complement KCL.It is mostly used in supply water of boiler and concentrated water of smoke ect.
GP500 complex electrode of high temperature strong acid 0~9pH 20~100℃ It is made of reference electrodes with special sensitive glass-velum and capillary Ag/AgCl of use chronically.It is applicable to the medium of high temperature strong acid.
GP700 pH complex electrode of endure alkali 3~14pH 5~60℃ It is made of reference electrodes with special sensitive glass-velum and capillary Ag/AgCl of use chronically.It is applicable to the special system of endure alkali.
GP800pH three complex electrode` 0~14pH 0~80℃ The three complex electrode is made up of glass-electrode,reference electrodes and temperature-electrode.It is easy used.
 
industrial ORP electrode type direction electrode applicable temperature application
GO100 ф6×2.5mm platinic golden loop 0~100℃ It is mostly used in industry and environment protection ect.

二、The Quotation Of Electrode Consult List:
type
name
quotation (RMB)

PH glass-electrode

211 type
30.42
221 type
30.42
231 type
30.42
65-I complex electrode
50.00
65-I complex electrode
50.00
E201 type-6
72.00
E201 type-9
72.00
320 type
30.00
320-2 type
30.00
305  type
30.00
305-2 type
30.00
3097 type
93.60
307-2 type
93.60
reference electrode
212 type
36.27
222 type
36.27
232 type
36.27
217 type
46.80
6802 type
36.27
type
name
quotation (RMB)
reference electrode
330 type
70.20
350 type
81.90
SHK type
93.60
conductance electrode
DJS-0.1
360.00
DJS-1C three core
60.00
DJS-1  black and white
72.00
DJS-10
50.00
DJS-5
550.00
260    black and white
120.00
metal electrode
213 type (platinum)
46.80
214 type (stibium)
29.25
215 type (stannum)
29.25
216 type (argent)
35.10
ion electrode
PK-I (kalium)
120.00
6801 (natrium)
70.20
PF-I (fluorin)
163.80
PCL-I (chlorin)
140.00
PNH3-I (ammonia)
187.20
 
mode name factory price annotate
GP100 800.00 electrode of sewage processing
GP100W 900.00 electrode of sewage processing plus temperature compensate
GP200 900.00 pure-water electrode
GP200W 1,000.00 pure-water electrode plus temperature compensate
GO300 900.00 ORP electrode
GO300W 1,000.00 ORP electrode plus temperature compensate
GP400 1,000.00 high temperature electrode and high temperature disinfection electrode
GP400W 1,200.00 high temperature electrode and high temperature disinfection electrode plus temperature compensate
GP500 1,000.00 strong acid electrode
GP500W 1,200.00 strong acid electrode plus temperature compensate
GP600 1,000.00 strong alkali electrode
GP600W 1,200.00 strong alkali electrode plus temperature compensate
三、KL Series Special Type Electrode:
 
product name
type product purpose
taper pH glass-electrode KL-851 It is applicable to determine pH original value in soil,water-system and vegetable ect.
full solid state taper pH electrode KL-842 It is applicable to determine pH original value in soil,water-system and vegetable ect.
flat shape pH electrode KL-741 It is applicable to determine pH original value in soil,water-system and vegetable ect.
minitype pH glass-electrode KL-869 It is applicable to determine pH value in dram sample of ocean,water quality,plant,chemical industry and sanitation ect.
minisize spinal shape pH electrode KL-8170 It is applicable to determine pH value in plant and sanitation ect.
minisize conglobate pH electrode KL-8170 It is applicable to determine pH value in plant and sanitation ect.
minisize flat shape pH electrode KL-8170 It is applicable to determine pH value in plant and sanitation ect.
plumbago electrode KL-099 It is applicable to determine direction electrode in reductive matter of soil,dirt and water-system ect.
taper conductance electrode KL-910 It is applicable to determine conductance of soil and paddy field ect.
tiny conductance electrode KLS-2 It is applicable to determine conductance value in soil,the leaf and fruit of plant and other dram sample ect.
tiny crop conductance electrode KLS-3 It is applicable to determine conductance value in soil,the leaf and fruit of plant and other dram sample ect.
minitype PNa electrode KL-8612 It is used in half of microanalysis.
oxygen electrode KL-9801 It is applicable to determine the content of oxygen in soil,water quality,environment protection and sanitation ect.
ammonia electrode KL-873 It is applicable to determine the content of nitrogen in soil,fertilizer and water quality ect.
kalium electrode KL-811 It is applicable to determine the content of kalium in soil, water-system and blood ect.
nitric acid radical electrode KL-813 It is applicable to determine the nitrogen in soil, fertilizer, water quality and vegetable ect.
sulfur electrode KL-731 It is applicable to determine the sulfur in soil,water quality,environment protection,petrifaction and take pictures ect.
iodine electrode KL-732 It is applicable to determine the iodine in soil and water quality ect.
bromine electrode KL-733 It is applicable to determine the bromine in soil and water quality ect.
medicine pH electrode KL-9403 It is applicable to determine pH value of blood.
medicine chlorin electrode KL-9404 It is applicable to determine chlorin value of blood.
medicine kalium electrode KL-9405 It is applicable to determine the content of kalium in blood.
medicine natrium electrode KL-9406 It is applicable to determine the content of natrium in blood.

 

 

Model Size
E201L
Dia.12×length 150mm
E201WL
Dia.12×length 150mm
E201WM
Dia.14×length 85mm
E201WS
Dia.12×length 50mm
E201XM
Dia.12×length 93mm
E201XL
Dia.12×length 147mm
E201
Dia.12×length 150mm
E201W
Dia.12×length 150mm
201DH
165mm×26mm×26mm
 


TOP